"Noisecuttrans" with the following specifications in standard type(F1, F3-F6 and G) is stocked.
- Fundamental wave frequency 50/60Hz (Others are custom-made.)
- Primary and secondary sides fundamental wave terminal voltage
1) Primary side 100V / Secondary side 100V
2) Primary side 200V / Secondary side 200V
3) Primary side 200V / Secondary side 100V
("Noisecuttrans" with other voltage or with over two taps is custom-made.)
- Phase
Single phase(In case of 3 phases, use 3 pieces of single phase, but 3 phases in one unit can be made order.)
- Insulation withstand voltage
AC 2000V (r.m.s) for a minute ("Noisecuttrans" of more than this is custom-made.)
- Impulse withstand voltage
1*40ƒÊS 5kV ("Noisecuttrans" of more than this is custom-made.)
- In case of using "Noisecuttrans" in 60Hz,
use the standard goods of 100V for 110V and 200V for 220V.
.
|
|
|